top of page
banner1.jpg

Fire Extinguisher

灭火器年度保养

海岸警卫队及渔业海洋部(Fisheries and Oceans Canada)规定船只灭火器必须要每年检查及做保养 .如果您的灭火器需要填充补料或是维修更新, 我们在每年船季开始时会安排专业灭火器厂商到我们办公室一起为大家的灭火器保修. 协助您做好安全设备维护!

过期遭遇临检可能会招致罚款

我们的服务优点:
  • 提供服务厂商透明估价, 与您自己询问的一样, 我们另酌收管理费, 没有隐藏或不透明的收费.

  • ​多年经验与专业训练, 在业界保持良好厂商关系, 能帮您推荐合适的服务商, 并且确实帮您把关.

  • ​省去您繁琐的联系工作.

以下是专业防火服务公司所提供的讯息

1) An Inspection of the fire extinguishers is in compliance and is conducted to the standards of National Fire Protection Association Standards (NFPA 10). 

专业检验灭火器必须遵照国家防火协会标准(NFPA 10)所订下的规范.

2) Once inspected, which is required annually, they are considered good at the time of service and left in serviceable working condition, certified for one year from the date of inspection. They are warrantied against leaking...but if they are used/discharged or damaged prior to the next annual inspection then a fee would apply to refilling/replacing.

在做完每年规定的检验之后,它们应被视为在维护时是在良好的并在可工作状态,合格期为自上次检查后一年,检验保证不外漏,但如在下一次检修之前有使用或喷洒,或是受损,那将会收取填补或更新费用。

3) All Dry Chemical extinguishers must endure annual inspect and also 6 years from date of manufacture they are to be given a 6 year maintenance, again this is a requirement from NFPA 10.(Standard for Portable Fire Extinguishers) 
所有的干式化学灭火器必须经过每年度的检验,同时在出厂六年以后,它们必须经过一次第六年整修,再度强调,这些都是NFPA 10所订定的程序(可移动式灭火器标准)。

4) Also Dry Chemical extinguishers that are 12 years from new, must endure a Hydro Static Test of the shell...in cases of 2.5 and 5 lb. extinguishers, pricing for this procedure is similar to replacing the extinguisher, however for 10 and 20lb. extinguishers a hydro static test is cost worthy if the extinguishers are still in decent shape.
干式化学灭火器当到了12年寿命时,必须进行钢瓶流体静力学测试(Hydrostatic Test)。不管是2.5磅或是5磅钢瓶,测试的花费将近等于购买全新同大小的钢瓶。然而,对于10或20磅的钢瓶将,测试的费用会相对的划算许多,前提是钢瓶必须在可以接受的状况之下。

5) Coast Guard/Department of Fisheries and Oceans also requires extinguishers for marine vessels to be inspected annually as does the insurer of your vessel, this applies to pleasure and commercial vessels, and in most cases the dock where vessel is moored requires this as well as part of mooring contract. 
海岸警卫队(Coast Guard)以及渔业海洋部(Department of Fisheries and Oceans)也要求航海船只所配备的灭火器于每年定期检测,而保险公司亦要求,这适用于私人游艇和商船。如果您的船是停泊在公众码头,绝大多数泊位合约中也包含相同的规定。

6) External Inspection includes:
*Gauge for pressure.
*Weighed for content.
*Dates for determination of maintenence or hydro.
*Hoses for blockage or cracks.
*Powder shaken or tapped to freely flow.

基本检测服务包含:
*检测量表压力值 
*内容物秤重 
*确认保养或检测日期 
*管线老化或堵塞 
*干粉重新混匀 

All this is done onsite or at our shop.
Upon completion..They are tagged with an inspection tag stating they pass inspection and are due for next inspection 1 year to the date. The tag states what was done to the extinguisher, the date of inspection, the date next inspection is due and the company and technician that performed the inspection. Including the technicians ASTT certified stamp.
All of this is supposed to be conducted by any fire company that services extinguishers. It's law.
这些检测可以现场服务或是在我们的检修中心完成。完成检测的灭火器会给与检测通过标示,同时注明一年后的复检日期。检测通过标示清楚注明已检测的项目还有是哪间公司的技术人员完成的检测。技术人员还需在标示盖上个人的ASTT颁发证明签。任何防火器维修公司必须依照这些程序,因为这是法律所规定。

7) 6 year maintenance fee applies if extinguisher is still full at time of doing this service. ...if it is empty due to discharge...only then does both recharge fee plus 6 year fee apply

当您的灭火器已达到6年了并且必须需要填充,您的费用将会是6年检测费加上填充补料费。要是您的灭火器6年了但不需要填充,您只需要支付6年检测费。

​常见问题:

灭火器检查是经过特别的游艇服务公司来进行吗?

不是的, 一般陆上专业防火服务公司就可以.

​灭火器有好多种, 是不是都可以用在船上?

只有干粉灭火器可以.

海龙灭火器因为有环境污染的问题, 已经禁止使用了.

​二氧化碳灭火器会让人在密闭的船舱里面窒息, 也不可以使用.

​除了每年定期检查, 平时还需要做什么保养吗?

​每个月灭火器上下颠倒, 用力摇晃, 以免内部的干粉长期积压结块, 影响效能.

​干粉灭火器可以喷喷试试看吗?

不可以, 一旦发射过, 内部的钢瓶就开始泄气, 很快就没有压力不能使用了.

bottom of page